Toward Worldwide Hepcidin Assay Harmonization: Identification of a Commutable Secondary Reference Material

Abstract Background:
Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal.
Methods:
We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material.
Results:
Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%.
Conclusions:
The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results.

DRG product(s) used in the study above

You can view the product details and buy it now

Hepcidin -25 (bioactive) HS Van der Vorm L.N., Hendriks J.C., Laarakkers C.M., Klaver S., Armitage A.E., Bamberg A., Geurts-Moespot A.J., Girelli D., Herkert M., Itkonen O., Konrad R.J., Tomosugi N., Westerman M., Bansal S.S., Campostrini N., Drakesmith H., Fillet M., Olbina G., Pasricha S.R., Pitts K.R., Sloan J.H., Tagliaro F., Weykamp C.W., Swinkels D.W.

Author Information

Clin Chem. 2016 Jul;62(7):993-1001.
© 2016 American Association for Clinical Chemistry.
Link: https://www.ncbi.nlm.nih.gov/pubmed/27173010

by Oleg Vishnevski | Jul 2, 2016

 
  • Events
  • News
  • Products
  • Uncategorized

DRG International, Inc.

841 Mountain Avenue
Springfield, NJ 07081 USA

Tel: +1-973-564-7555
Fax: +1-973-564-7556

Copyright © 2022.
DRG International Inc.
All Rights Reserved.
PCI Compliance Certification

Subsidiaries

  • USA
  • Germany
  • Russia – Moscow
  • Russia – St Petersburg
  • Poland
  • Czech Republic

Support

  • Order Information
  • Troubleshooting

Shortcuts

  • Login
  • Terms of Use
  • Privacy Policy
  • Privacy Preferences
  • Privacy Policy
  • Cookie Policy
  • Facebook
  • Twitter
  • Google
  • RSS
  • linkedin
  • instagram

Designed by Walnut St. Labs